SPECIFICATIONS
Metric
Order No
| Range
| Accuracy*
| Flatness
| Parallelism
|
293-582
| 300-325mm | ±6μm
| 0.6μm
| 5μm
|
293-583 | 325-350mm |
293-584 | 350-375mm |
293-585 | 375-400mm | ±7μm | 6μm |
293-586 | 400-425mm |
293-587 | 425-450mm |
293-588 | 450-475mm | ±8μm |
293-589 | 475-500mm | 7μm |
* Excluding quantizing error
Inch/Metric
Order No
| Range
| Accuracy*
| Flatness
| Parallelism
|
293-782
| 12"-13" | ±.0003”
| .000024”
| .0002”
|
293-783 | 13"-14" |
293-784 | 14"-15" |
293-785 | 15"-16" | ±.00035” | .00024” |
293-786 | 16"-17" |
293-787 | 17"-18" |
293-788 | 18"-19" | ±.0004” |
293-789 | 19-"20" | .00028” |
* Excluding quantizing error
Technical Data
- Resolution: 0.001mm or .0001”/0.001mm
- Measuring force: 10 to 15N SR44 (2 pc), 938882, for initial operational checks (standard accessory)
- Battery life: Approx. 1.8 years under normal use
- Length standard: Electromagnetic rotary sensor
- Standard accessories: Reference bar, 1 pc
- Spanner (200154), 1 pc
Functions
- Origin point setting (ABS measurement system):
Resets the ABS origin at the current spindle position to
the minimum value of the measuring range and switches
to ABS mode. - Zero-setting (INC measurement system):
A brief press on the ZERO/ABS button sets display to
zero at the current spindle position and switches to the
incremental (INC) measuring mode. A longer press resets
to the ABS measuring mode. - Hold:
Pressing the HOLD button freezes the current value
in the display. This function is useful for preserving a
measurement in situations of poor visibility where the
instrument must be moved away from the workpiece
before the reading can be recorded. - Function lock:
This function allows the PRESET (origin point setting)
function and the ZERO (zero-setting) function to be
locked to prevent these points being reset accidentally. - Auto power ON/OFF:
The reading on the LCD disappears after this instrument
is idle for about 20 minutes, but the reading and
measurement mode are retained. Turning the spindle
causes the reading to reappear. - Data output:
Models equipped with this function have an output port
for transferring measurement data to a Statistical Process
Control (SPC) system. - Error alarm:
In case of an overflow on the LCD or a computing error,
an error message appears on the LCD, and the measuring
function stops. This prevents an instrument from giving an
erroneous reading. Also, when the battery voltage drops to
a certain level, the low-battery-voltage alarm annunciator
appears well before the micrometer becomes unusable.